0 / 00 / 0Mate / 0i Model A
A parameter that requires power-off was changed. Turn the machine off and on again.
TH alarm: character with wrong parity read from tape. Fix the source.
TV alarm: odd number of characters in a block (only occurs with TV check on).
Value exceeds the maximum number of digits allowed for the address.
Number or '-' sign at the start of a block with no address. Put the letter (X, Z, F...) first.
Address without a value: another address or EOB came in place of the data.
'-' sign error: used on an address that doesn't accept it, or two '-' in the same value.
Decimal point on an address that doesn't accept it, or two points in the same value.
Invalid character in the significant area of the program.
G code not recognized by the control.
Feed F missing or invalid during cutting.
Axis outside the selected plane (G17/G18/G19) used in circular interpolation.
Circular interpolation with negative R — not allowed.
Offset value specified by H (mill) or T (lathe) is too large.
Offset number H (mill) or T (lathe) exceeds the allowed range.
Intersection point cannot be calculated in cutter compensation.
Start-up or cancel of compensation was done in G02/G03. Always do it in G01.
Overcut will occur in cutter radius compensation.
Chamfer or corner radius specified in a threading block.
Sequence number N not found on search.
P or Q missing in G70, G71, G72 or G73.
Program memory full. Delete old programs.
Specified address or data was not found.
Number of programs exceeds the storable limit.
Program number already exists. Choose another O####.
Program number outside the 1–9999 range.
Address P missing in M98 or G65.
Subprogram nested 3 or 5 levels deep (limit exceeded).
Program or sequence called by M98/M99/G66 not found.
PWE parameter is set to 1. Set it to 0 and reset.
Manual return to the X-axis reference point is required.
Communication error on the X-axis absolute encoder.
Timeout on X-axis APC communication.
Y-axis APC battery very low — data may be lost. Replace the battery.
Y-axis APC battery voltage at replacement level.
X-axis position deviation exceeds setup value at stop. Check load and drive.
X-axis position deviation during motion exceeds setup.
X encoder position detection failure (break alarm).
Overtravel: X-axis (+) limit exceeded.
Overtravel: X-axis (–) limit exceeded.
2nd overtravel limit on (+) side of X-axis exceeded.
Overtravel: Z-axis (+) limit exceeded.
Overtravel: Z-axis (–) limit exceeded.
Interrupt caused by illegal instruction in PMC.
Parity error in PMC RAM.
PMC serial transmission error.
PMC watchdog tripped.
ROM parity error. Replace the master board.
RAM parity error (low byte). Replace the master board.
Watchdog alarm. Replace the master board.
CPU error (abnormal interrupt). Replace the master board.
Blown fuse (T24E:F14). Replace the fuse.